ReadyPlanet.com
dot dot
bullet»ÑêÁ¹éӴѺà¾ÅÔ§
bulletµÙéà¡çºÍØ»¡Ã³ìáÅÐÊÒÃà¤ÁÕ
bulletÃкº·Ó¤ÇÒÁàÂç¹
dot

ËÁÇ´ÊÔ¹¤éÒ
ÂÕèËéÍÊÔ¹¤éÒ

  [Help]
dot


Add friend


â¹µÔ¿Ò FZM-1 Zone Interface Monitor Module Áҵðҹ UL/FM  
Honeywell Notifier FZM-1 Zone Interface Monitor ModuleHoneywell Notifier FZM-1 Zone Interface Monitor Module
Honeywell Notifier FZM-1 Zone Interface Monitor Module
ÃËÑÊ : 46FZM1
ÂÕèËéÍ : NOTIFIER by Honeywell, USA
ÃØè¹ : FZM-1
ÃÒ¤Ò»¡µÔ :  1,500.00      
ÃÒÂÅÐàÍÕ´ÂèÍ :
NOTIFIER by Honeywell FZM-1, Intelligent Addressable Zone Interface Monitor Module 2-wire, UL/FM, USA

FZM-1 Interface Module
ÃÒÂÅÐàÍÕ´·Ñé§ËÁ´ :

Notifier FZM-1 (Zone Interface Module) ¤×ÍâÁ´ÙÅÃѺÊÑ­­Ò³ª¹Ô´·ÕèµéͧÁÕä¿àÅÕé§ (Addressable Module) ·Ó˹éÒ·Õèàª×èÍÁµèÍÍØ»¡Ã³ìµÃǨ¨Ñº¤ÇѹẺ·ÑèÇä» (2-Wire Conventional Detectors) à¢éҡѺµÙé¤Çº¤ØÁÊÑ­­Ò³á¨é§à˵Øà¾ÅÔ§äËÁ骹Դ·ÕèÃкصÓá˹è§ä´é (Addressable Panel) ªèÇÂãËéµÙé¤Çº¤ØÁÃÙéʶҹР(»¡µÔ/á¨é§à˵Ø/ÊÒ¢Ҵ) ¢Í§â«¹¹Ñé¹ä´é 

¤Ø³ÅѡɳÐ

¡Ò÷ӧҹ: à»ÅÕèÂ¹ÍØ»¡Ã³ì Conventional Ẻ 2 ÊÒ ãËéÊÒÁÒöÃкصÓáË¹è§ (Address) ä´é

¡ÒÃàª×èÍÁµèÍ: ÃͧÃѺ¡ÒÃà´Ô¹ÊÒÂÁҵðҹ Class B (Style B) ËÃ×Í Class A (Style D)

ʶҹÐ: ÁÕ LED áÊ´§Ê¶Ò¹Ð¡Ò÷ӧҹ (¡Ð¾ÃÔºàÁ×èÍ»¡µÔ, ¤éÒ§àÁ×èÍ Alarm)

¡ÒõÑ駤èÒ: ãªéÊÇÔµªìẺËÁع (Rotary Switches) 㹡ÒõÑ駤èÒ·ÕèÍÂÙè (Address) ¢Í§âÁ´ÙÅ

Áҵðҹ: Áҵðҹ UL/FM áÅÐà»ç¹¼ÅÔµÀѳ±ì¨Ò¡ÊËÃѰÍàÁÃÔ¡Ò 

¡ÒÃãªé§Ò¹ËÅÑ¡

ãªéàª×èÍÁµèÍÍØ»¡Ã³ìµÃǨ¨Ñº¤Çѹ (Smoke Detector) ËÃ×ÍÍØ»¡Ã³ìµÃǨ¨Ñº¤ÇÒÁÃé͹ (Heat Detector) Ẻ 2 ÊÒÂ

ãªé㹡óշÕèµéͧ¡ÒüÊÁÃкº Conventional à¢éҡѺÃкº Addressable 

¢éͤÇÃÃÐÇѧ
ÍØ»¡Ã³ìµÃǨ¨Ñº¤Çѹ·Õè¹ÓÁÒµè͡Ѻ FZM-1 µéͧà»ç¹áºº·ÕèÃкØÇèÒãªé§Ò¹ÃèÇÁ¡Ñ¹ä´é (Compatible) ¡ÑºâÁ´ÙŹÕé

FZM-1 (A) Interface Module is intended for us in intelligent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligents panels to interface an monitor two-wire conventional smoke detectors. It transmits the status (normal, open, or alarm) of one full zone of conventional detectors back to the contraol panel. All two-wire detectors being monitored must be UL compatible with the module. The FZM-1(A) can be used to replace MMX-2(A) modules in existing systems

Application:
Use to monitor a zone of two-wire smoke detectors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 3.9K Ohm End-of-Line Resistor (provided) terminates the end of the Style B or D (Class B or A) circuit (maximum IDC loop resistance is 25 Ohms). Install ELR across terminals 8 and 9 for Style D application.

Specification:
Nominal operating voltage: 15 to 32VDC
Maximum current draw: 5.1mA (LED on).
Maximum IDC wiring resistance: 25 Ohms
EOL resistance: 3.9 Ohms

 

 

 



ÀÒ¾¶èÒ·Ñé§ËÁ´·Õè»ÃÒ¡®º¹àÇçºä«·ì à»ç¹ÅÔ¢ÊÔ·¸Ôì¢Í§ºÃÔÉÑ· áªÁ»ìÁÒÃìà¡çµµÔé§ ¨Ó¡Ñ´ ËéÒÁ¹Óä»ãªéâ´ÂäÁèä´éÃѺ͹حҵ ËÒ¡½èÒ½×¹ ¨Ð¶Ù¡´Óà¹Ô¹¤´ÕµÒÁ¡¯ËÁÒ Copyright © 2010-2026 All Rights Reserved.

ÃÒ¤ÒÊÔ¹¤éÒ·ÕèáÊ´§ã¹àÇçºä«·ì ÂѧäÁèÃÇÁ¤èҨѴÊè§áÅÐÀÒÉÕÁÙŤèÒà¾ÔèÁ
**ʧǹÊÔ·¸Ôì㹡ÒÃà»ÅÕè¹á»Å§ÃÒ¤Ò¨Ó˹èÒ áÅТéÍÁÙżÅÔµÀѳ±ìâ´ÂäÁèá¨é§ãËé·ÃÒºÅèǧ˹éÒ**
ºÃÔÉÑ· áªÁ»ìÁÒÃìà¡çµµÔé§ ¨Ó¡Ñ´
233/3-4 ¶¹¹ÊÃþÒÇØ¸ á¢Ç§ºÒ§¹Òãµé ࢵºÒ§¹Ò ¡Ãا෾ÁËÒ¹¤Ã 10260 »ÃÐà·Èä·Â
Email: ChampMarketing@gmail.com Tel: 02-183-5349-50
*Êͺ¶ÒÁ¢éÍÁÙÅËÃ×ÍÊÑè§«×éÍÊÔ¹¤éÒ ¡ÃØ³Ò Add LINE ID: @champmarketing

¤ÅÔ¡Êͺ¶ÒÁÊÔ¹¤éÒ