â¹µÔ¿Ò FMM-1 Monitor Module Áҵðҹ UL/FM  
Notifier FMM-1 Monitor Module Áҵðҹ UL/FMNotifier FMM-1 Monitor Module Áҵðҹ UL/FM
ÃËÑÊ : 46FMM1
ÂÕèËéÍ : NOTIFIER by Honeywell
ÃØè¹ : FMM-1 (FMM-1CH, FMM-1/N)
ÃÒ¤Ò»¡µÔ :  1,400.00      
ÃÒÂÅÐàÍÕ´ÂèÍ :
NOTIFIER by Honeywell FMM-1 Intelligent Addressable Single Switch Input Module, 24VDC, UL listed, USA

FMM-1 Monitor Module
ÃÒÂÅÐàÍÕ´·Ñé§ËÁ´ :
Notifier FMM-1 ¤×Í ÍØ»¡Ã³ìÁ͹ÔàµÍÃìâÁ´ÙÅÃкصÓáË¹è§ (Addressable Monitor Module) ã¹Ãкºá¨é§à˵Øà¾ÅÔ§äËÁé (Fire Alarm System) ÂÕèËéÍ Notifier by Honeywell ·Ó˹éÒ·Õèà»ç¹µÑÇ¡ÅÒ§àª×èÍÁµèÍÍØ»¡Ã³ìàÃÔèÁÊÑ­­Ò³Ãкº¸ÃÃÁ´Ò (Conventional) ËÃ×ÍÍØ»¡Ã³ì·ÕèÁÕ˹éÒÊÑÁ¼ÑÊáËé§ (Dry Contact) ãËéÊÒÁÒöÊè§ÊÑ­­Ò³áÅÐ ÃкصÓá˹觨شà¡Ô´à˵Øä»ÂѧµÙé¤Çº¤ØÁËÅÑ¡ (Fire Alarm Control Panel) ä´éÍÂèÒ§áÁè¹ÂÓ 
 
˹éÒ·ÕèáÅСÒ÷ӧҹ
* á»Å§ÍØ»¡Ã³ì¸ÃÃÁ´ÒãËéÃкصÓá˹è§ä´é: àª×èÍÁµèÍÍØ»¡Ã³ì»ÃÐàÀ·Ë¹éÒÊÑÁ¼ÑÊ»¡µÔà»Ô´ (Normally Open ËÃ×Í N.O.)
* µÃǨÊͺÊÀÒÇÐÊÒÂÊÑ­­Ò³: µÃǨÊͺà˵ØÊÒ¢Ҵ (Open Circuit) â´ÂãªéµÑǵéÒ¹·Ò¹»ÅÒÂÊÒ (EOL Resistor) ¢¹Ò´ 47K Ohms
* äÁèµéͧãªéä¿àÅÕé§á¡: ÃѺ¡ÃÐáÊä¿â´ÂµÃ§¨Ò¡ÊÒÂÊÑ­­Ò³ Loop (SLC Loop) ¢Í§Ãкº
* áÊ´§Ê¶Ò¹Ð´éÇÂä¿ LED: ä¿ÊÕà¢ÕÂǡоÃÔºã¹ÊÀÒÇл¡µÔ áÅÐà»ÅÕè¹à»ç¹ÊÕá´§µÔ´¤éÒ§àÁ×èÍÍØ»¡Ã³ì·Ó§Ò¹ (Active) 

ÍØ»¡Ã³ì·Õè¹ÔÂÁ¹ÓÁÒàª×èÍÁµèÍ
* Manual Pull Station / Manual Call Point: ÍØ»¡Ã³ìá¨é§à˵Øà¾ÅÔ§äËÁé´éÇÂÁ×Í
* Heat Detector / Smoke Detector: ÍØ»¡Ã³ìµÃǨ¨Ñº¤ÇÒÁÃé͹ËÃ×ͤÇѹ (ÃØè¹¸ÃÃÁ´Ò)
* Waterflow Switch: ÊÇÔµªìµÃǨ¨Ñº¡ÒÃäËŢͧ¹éÓã¹Ãкº´Ñºà¾ÅÔ§
* OSY Gate Valve / Tamper Switch: ÊÇÔµªìµÃǨÊͺ¡ÒûԴ-à»Ô´¢Í§ÇÒÅìǹéÓ 
 
¤Ø³ÊÁºÑµÔ·Ò§à·¤¹Ô¤
¡ÒõÑé§ Address: ãªéÊÇÔµªìẺËÁع (Rotary Switches) »ÃѺ¤èÒä´éµÑé§áµè 01 ¶Ö§ 159 (Ãкº FlashScan)
áç´Ñ¹ä¿·Ó§Ò¹: 15 ¶Ö§ 32 VDC

 

ÁҵðҹÃͧÃѺ: ¼èÒ¹¡ÒÃÃѺÃͧÊÒ¡Å àªè¹ UL Listed, FM Approved

The Notifier FMM-1 Monitor Module is a standard-sized module that supervises either a Style D (Class A) or Stle B (Class B) circuit of dry-contact input devices. For use in intelligent, two-wire systems.

Applications:
Use to monitor a single device or a zone of four-wire smoke detectors, manual fire alarm pull station, waterflow devices, or other normally-open dry-contact devices, May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored cir-cuit/device is wired as an NFPA Style B (Class B) Initiating Device Circuit, A 47Ohm End-of Line Resistor (provied) terminates the circuit.  

Product Label: FMM-1
Legacy Ordering Part Code: FMM-1-CH
New Ordering Part Code: FMM-1/N 



ÀÒ¾¶èÒ·Ñé§ËÁ´·Õè»ÃÒ¡®º¹àÇçºä«·ì à»ç¹ÅÔ¢ÊÔ·¸Ôì¢Í§ºÃÔÉÑ· áªÁ»ìÁÒÃìà¡çµµÔé§ ¨Ó¡Ñ´ ËéÒÁ¹Óä»ãªéâ´ÂäÁèä´éÃѺ͹حҵ ËÒ¡½èÒ½×¹ ¨Ð¶Ù¡´Óà¹Ô¹¤´ÕµÒÁ¡¯ËÁÒ Copyright © 2010-2026 All Rights Reserved.

ÃÒ¤ÒÊÔ¹¤éÒ·ÕèáÊ´§ã¹àÇçºä«·ì ÂѧäÁèÃÇÁ¤èҨѴÊè§áÅÐÀÒÉÕÁÙŤèÒà¾ÔèÁ
**ʧǹÊÔ·¸Ôì㹡ÒÃà»ÅÕè¹á»Å§ÃÒ¤Ò¨Ó˹èÒ áÅТéÍÁÙżÅÔµÀѳ±ìâ´ÂäÁèá¨é§ãËé·ÃÒºÅèǧ˹éÒ**
ºÃÔÉÑ· áªÁ»ìÁÒÃìà¡çµµÔé§ ¨Ó¡Ñ´
233/3-4 ¶¹¹ÊÃþÒÇØ¸ á¢Ç§ºÒ§¹Òãµé ࢵºÒ§¹Ò ¡Ãا෾ÁËÒ¹¤Ã 10260 »ÃÐà·Èä·Â
Email: ChampMarketing@gmail.com Tel: 02-183-5349-50
*Êͺ¶ÒÁ¢éÍÁÙÅËÃ×ÍÊÑè§«×éÍÊÔ¹¤éÒ ¡ÃØ³Ò Add LINE ID: @champmarketing

¤ÅÔ¡Êͺ¶ÒÁÊÔ¹¤éÒ